Herd security
for a high health farm
|
|
Basic Design
|
|
1
|
The unit must be surrounded by a complete fence
|
|
2
|
The fence should be 2.4m (8ft) high and 500mm (1.5ft)
buried underground to stop pigs and other mammals
entering and leaving the unit.
|
|
3
|
A car park should be sited away from the unit and
appropriately marked.
|
|
4
|
All entrances through the fence must be locked.
|
|
5
|
All personal items including personal clothing,
watches, cigarette lighters etc. must remain outside of
the unit itself.
|
|
6
|
All staff and visitors must wear unit clothing.
|
|
7
|
Spectacles, cameras and other visitor equipment must be
inspected by a member of staff before being allowed
onto the unit. Spectacles should be washed.
|
|
8
|
All meters (electrical, gas and water) must be situated
outside the unit fence and placed in a locked area.
|
|
9
|
The farm manager's office should be situated near the
entrance.
|
|
10
|
A Klaxon switch should be placed by the car park to
attract staff attention to visitors.
|
|
11
|
None of the staff should own or come into contact with
other pigs.
|
|
12
|
No staff should visit animal markets, pig shows or
slaughterhouses.
|
|
13
|
No unauthorised pigs, pig products or pig faecal
material must be allowed onto the farm.
|
|
14
|
Unit rules regarding last pig contact must be strictly
adhered too, including signing the visitor's book.
|
|
15
|
All entry and exit points should be well lit, ideally
with proximity sensors.
|
|
16
|
On many high health units all visitors must shower.
|
|
The Following Entrances/Exits are Permitted
|
|
1
|
Entrance via a locked door into staff shower facility.
|
|
2
|
Entrance via a locked door into a visitor shower
facility.
|
|
3
|
Connector to the feed bins which pass through the
fence.
|
|
4
|
Exit via a raised ramp for livestock.
|
|
5
|
Exit for dead animal disposal through a locked gate.
|
|
6
|
The straw barn has an entrance from off-farm and an
entrance on-farm. Both should be kept locked. Staff are
not allowed to leave the farm through the straw barn.
|
|
7
|
Slurry disposal through underground pipe to slurry
store off-farm.
|